AI in Emergency Medicine

AI Pneumothorax Flags on Chest X-Ray: What a Clean Read Means

Chester Shermer, MD, FACEP • November 19, 2026
AI Pneumothorax Flags on Chest X-Ray: What a Clean Read Means

Why this matters

An AI overlay finds no pneumothorax on a supine trauma film. What the commercial tools detect on supine and upright films, why chest tubes fooled early algorithms, and when to look again with ultrasound or CT.

Recommended next step

Pair this article with the free guide or course store if you want a more structured framework you can apply at the bedside or in leadership conversations.

At 1915 a 67-year-old farmer arrives by ambulance after falling about eight feet from a hayloft onto his right side. He has right lateral chest wall tenderness with crepitus, a shortened and externally rotated right leg, a heart rate of 96 and an SpO2 of 94% on 2 L by nasal cannula. On the eFAST, subcutaneous air along the right lateral chest wall makes the lung views hard to read. His trauma CT is ordered and the scanner is busy. The portable supine chest film posts to the viewer with the vendor's overlay attached, and the AI has drawn nothing: no pneumothorax flag. Orthopedics wants his hip repaired under general anesthesia in the morning.

That empty overlay tells you less than it looks like. In a CT-referenced study of one commercial tool on supine films, a negative read made a large pneumothorax unlikely. It did not rule out the small or basal one that matters once this man is on a ventilator.

What the Headline Numbers Describe

A 2024 meta-analysis of 23 studies (34,011 patients) found deep-learning pneumothorax detection on chest radiographs had a pooled sensitivity of 87% and specificity of 95% [1]. Those figures pool many tools and datasets and hide the cases you worry about.

A Danish study ran four commercially available tools on 2,040 consecutive adult chest radiographs from four hospitals, against a reference standard set by thoracic radiologists who could see all prior and later imaging [2]. Pneumothorax sensitivity ranged from 63% to 90% depending on the product, with areas under the curve of 0.89 to 0.97. Negative predictive values for the target findings ranged from 92% to 100%. Sensitivity fell for small findings: for a small pneumothorax or pleural effusion it ranged from 9% to 94% across tools. The tools also produced more false-positive findings than the radiology reports did [2].

Your department runs one product at one threshold, and its numbers are the only ones that apply to your patients.

The Supine Film Problem

A 2020 Cochrane review included 13 prospective paired studies. In the nine that analyzed patients (1,271 ED trauma patients, 410 with pneumothorax), it found a summary sensitivity for supine chest radiography of 47%, against 91% for chest ultrasound performed by frontline non-radiologist physicians; specificity was similar for both [3]. All 13 studies carried a high or unclear risk of bias in at least one domain. Those were physicians reading the films. In the CT-referenced study of one commercial tool on supine films below, the AI found 61.0% [4]; the population and reference standard differ, but most of the gap to ultrasound remains.

A 2026 University of Tokyo study measured what one commercial tool does on supine films from ED and ICU patients, using CT within six hours as the reference [4]. It analyzed 114 hemithoraces with pneumothorax and 340 without. Overall sensitivity was 61.0% and specificity 94.3%. For large pneumothoraces, defined as a maximum radial interpleural distance over 35 mm on CT, sensitivity was 97.4%, though that subgroup was small and its confidence interval wide. For pneumothoraces of 35 mm or less, sensitivity was 44.9%. Sensitivity was higher in the upper lung zone than in the lower zone (69.5% against 37.5%) [4]. In their discussion, the authors caution that a negative AI result does not exclude pneumothorax, particularly a small one in the lower zone, and clinicians should stay alert in patients at risk of progression, such as those on positive-pressure ventilation [4].

Its 19 false positives are a useful list of what to check before you act on a flag: skin folds (10), bullous emphysema (4), external devices (2), subcutaneous emphysema (2) and post-cardiothoracic surgery change (1) [4]. In its reader study of six intensivists, the tool raised residents' sensitivity from 46.8% to 57.3%, did not change the experts' sensitivity significantly, and raised the experts' specificity from 90.9% to 95.6% [4]. The cohort was mostly non-trauma; only 26% of the pneumothorax patients had been injured.

Upright Films: Where the Flag Earns Its Place

On a standard upright PA film, the evidence favors the flag. In a 2026 single-center study from Türkiye, 920 consecutive ED adults had a PA chest radiograph and a chest CT within four hours [5]. Against CT, a commercial tool detected 90.8% of the 65 pneumothoraces with a specificity of 99.8%. One emergency physician with 10 years of experience, reading the same films blinded to clinical information and prior imaging, detected 50.8%. Nearly half of the CT-confirmed pneumothoraces (47.7%) were found by the AI alone [5]. Three caveats: portable AP films were excluded, a single reader without clinical context is a harder test than real practice, and because the AI output was visible in routine care, it may have influenced who got a CT. The authors say the results support testing AI as a second reader in prospective studies; they do not show that real-time AI help improves care [5].

A Munich reader study agreed. Three ED-experienced non-radiology residents read 563 upright PA emergency unit radiographs, enriched for findings, with and without AI overlays. Against the most sensitive of four reference standards, set by three board-certified radiologists whose reads included AI-assisted ones, their consensus area under the curve for pneumothorax rose from 0.846 to 0.974, and sensitivity at a fixed specificity rose from 71% to 93% [6]. Radiology residents, already near the ceiling, gained little.

In a 2026 online simulation, 231 physicians in Türkiye read 20 CT-confirmed PA films; after the AI overlay, stated intent to order CT rose from 8.1% to 26.7%, mostly in true-positive cases [7]. It measured intent, not orders.

Chest Tubes, Training Data and Chatbots

Some pneumothorax algorithms learned the wrong feature. A Munich team tested two algorithms trained on public datasets against 6,434 supine films [8]. A chest tube in the image acted as a strong confounder: when the comparison set pneumothoraces without tubes against tube-bearing films without pneumothorax, discriminative power disappeared entirely. The same group later showed that training with in-image annotation of the pleural edge reduced that bias [9], and in the Tokyo study, chest tube status did not differ between pneumothoraces the commercial tool caught and missed (45% against 42%) [4]. Ask your vendor whether the product was tested on films with tubes in place.

General-purpose chatbots are not pneumothorax detectors. In a 2026 single-center retrospective study of 265 pneumothorax cases and 267 controls, ChatGPT had a sensitivity of 44.5% and Gemini 52.5%, against 64.5% sensitivity and 99.6% specificity for 13 emergency physicians reading the same images [10].

What to Do on the Shift

Read the film yourself before you open the overlay, so the flag checks your read rather than replacing it; the automation bias problem is real when the answer arrives first. On a supine trauma film, treat an empty overlay as information about large pneumothoraces only. If the mechanism, the exam or the plan for positive-pressure ventilation makes a small pneumothorax matter, look with ultrasound or CT; AI-assisted point-of-care ultrasound has its own limits to know. On a positive flag, find the pleural line yourself and rule out a skin fold or a bulla before you reach for a chest tube. The same logic applies to AI brain bleed alerts on head CT: a negative flag is only as good as the cases the tool was tested on.

For the farmer, the empty overlay settles nothing. Repeat the lung ultrasound with care over the anterior and basal chest, and make sure someone reads the chest CT he needs tonight anyway before he goes to the operating room.

Key Takeaways

  • On supine films, one commercial tool detected 97.4% of pneumothoraces over 35 mm but only 44.9% of smaller ones, and 37.5% in the lower lung zone [4].
  • Physicians reading supine trauma films found about half of pneumothoraces (summary sensitivity 47% against 91% for ED chest ultrasound) [3]; one AI tool did somewhat better on supine films (61.0%) [4], but most of the gap to ultrasound remains.
  • On upright PA films, a commercial tool detected 90.8% of CT-confirmed pneumothoraces against 50.8% for one blinded emergency physician reading independently [5]; the authors say benefit from real-time AI help is not yet established.
  • Commercial products differ: pneumothorax sensitivity ranged from 63% to 90% across four tools on the same 2,040 films [2]. Ask for your product's numbers on supine films and on films with chest tubes.

FAQ

How accurate is AI at detecting pneumothorax on a chest X-ray?

Pooled across 23 studies and many different tools, sensitivity was 87% with 95% specificity [1]. Commercial tools vary: on the same 2,040 films, four products ranged from 63% to 90% sensitivity [2]. Accuracy drops for small pneumothoraces and on supine films [2,4].

Can a negative AI read rule out a pneumothorax?

Not on a supine film. In one CT-referenced study, a commercial tool missed more than half of pneumothoraces of 35 mm or less and most of those in the lower lung zone [4]. When a small pneumothorax would change management, use ultrasound or CT [3,4].

Why does AI flag a pneumothorax that is not there?

The most common cause in one study was a skin fold mimicking the pleural line, followed by bullous emphysema, external devices, subcutaneous emphysema and post-surgical change [4]. Two older algorithms trained on public data also learned to associate chest tubes with pneumothorax [8]. Confirm the pleural line yourself before acting.

Dr. Chet's Take

I have practiced emergency medicine for more than 25 years, and I now work at a Level I academic trauma center. This article is right about where the danger sits. The flag is strongest on the upright film and weakest on the supine film, and the supine film is the one we lean on hardest in the trauma bay. That is not a reason to switch it off. On the upright film of the tall young man with sudden chest pain, a second reader that never gets tired will catch the thin apical line we sometimes skate past at the end of a long shift. The core argument holds: know which film your tool is good at, and stop extending its confidence to the films it was never good at.

That being said, the hardest part of this problem is not in any accuracy table. The supine film is often the first image a sick patient gets, and a clean overlay makes it easier to talk yourself out of the next one, or to let the next one sit unread. The honest answer is that the risk is not the false negative itself. It is what a confident-looking negative does to the plan. As a HEMS and critical care transport medical director, I care about the patient who leaves your department on a ventilator and goes into a helicopter or an ambulance with no way to get a film on the way. The transport crew cannot re-read your film in the aircraft. They inherit your conclusion.

If you are the attending, decide before the shift which patients get an ultrasound regardless of what the overlay says: the intubated, the patient headed for positive-pressure ventilation, and the patient leaving on a transport. Write that list down and put it where the night team will see it, not in a policy binder. If you are leading an emergency department, do not wait for the vendor to tell you how the product behaves on your patients. Have your radiology partners pull every supine portable film from the last few months that was followed by a chest CT, and put the overlay beside the CT read. A few dozen pneumothoraces will teach your group more about this tool than any brochure. Until you have that answer, the empty overlay on a supine film tells you, at most, that a large pneumothorax is unlikely, and nothing about the small or basal one. A tool you have never measured is a tool you cannot trust at 0200.

— Chester Shermer, MD, FACEP | Emergency Medicine, 25+ Years Clinical Experience | State Surgeon

Continue Your Training

If you're an emergency physician (or any clinician treating patients daily) trying to understand how AI will actually impact your clinical practice — not just the hype — I put together a free practical guide. You can download the AI in EM Survival Guide here.

Browse All Courses at Global MedOps Command

Relevant Reading on Global MedOps Command:

How to Avoid Becoming an AI Casualty — Dr. Shermer's guide to navigating AI tools in clinical and operational settings without compromising judgment or patient outcomes.

Emergency Department Efficiency Playbook — Practical systems for throughput, triage optimization, and operational efficiency.

Read more from Dr. Shermer on Medium

Connect with Dr. Shermer: LinkedIn — Chester "Chet" Shermer, MD, FACEP.

References

  1. Katzman BD, Alabousi M, Islam N, et al. Deep Learning for Pneumothorax Detection on Chest Radiograph: A Diagnostic Test Accuracy Systematic Review and Meta Analysis. Can Assoc Radiol J. 2024;75(3):525-533. PubMed 38189265
  2. Lind Plesner L, Müller FC, Brejnebøl MW, et al. Commercially Available Chest Radiograph AI Tools for Detecting Airspace Disease, Pneumothorax, and Pleural Effusion. Radiology. 2023;308(3):e231236. PubMed 37750768
  3. Chan KK, Joo DA, McRae AD, et al. Chest ultrasonography versus supine chest radiography for diagnosis of pneumothorax in trauma patients in the emergency department. Cochrane Database Syst Rev. 2020;7(7):CD013031. PubMed 32702777
  4. Nakamura H, Wada T, Inokuchi R, et al. Performance of an artificial intelligence-based software in detecting pneumothorax on supine chest radiographs: a retrospective study. Emerg Radiol. 2026;33(2):281-290. PubMed 41807842
  5. Damar Ö, Yaman M. CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study. Tomography. 2026;12(10):142. PubMed 42931486
  6. Rudolph J, Huemmer C, Preuhs A, et al. Nonradiology Health Care Professionals Significantly Benefit From AI Assistance in Emergency-Related Chest Radiography Interpretation. Chest. 2024;166(1):157-170. PubMed 38295950
  7. Cırıl MF, Yıldız F, Akarca M. Artificial intelligence as a second reader for pneumothorax detection: redirecting rather than reducing chest CT use. BMC Emerg Med. 2026;26(1). PubMed 42393541
  8. Rueckel J, Trappmann L, Schachtner B, et al. Impact of Confounding Thoracic Tubes and Pleural Dehiscence Extent on Artificial Intelligence Pneumothorax Detection in Chest Radiographs. Invest Radiol. 2020;55(12):792-798. PubMed 32694453
  9. Rueckel J, Huemmer C, Fieselmann A, et al. Pneumothorax detection in chest radiographs: optimizing artificial intelligence system for accuracy and confounding bias reduction using in-image annotations in algorithm training. Eur Radiol. 2021;31(10):7888-7900. PubMed 33774722
  10. Cakiroglu OF, Arac B, Calisir SN, et al. Comparison of emergency physicians and artificial intelligence models in pneumothorax detection: A multi-reader retrospective study. Medicine (Baltimore). 2026;105(25):e49412. PubMed 42332528

Related simulation training: EM-Sim · Books by Dr. Shermer

Keep reading

Related reading and your next step.

Ready to go further? Move from this article into structured training, scenario-based rehearsal, and more physician-written guidance.

Course

Translate the article into a repeatable framework

Use the physician-led course when you want a structured framework for evaluating AI tools, protecting clinical judgment, and leading implementation decisions.

Simulation

Practice the decision path under pressure

Use EM-Sim when you want scenario-based repetition that turns article-level insight into physician-facing emergency-medicine reps.

Blog

Browse more articles

Explore the full blog for more on AI in emergency medicine, then head to the course and simulation pages when you want the structured next step.

By using this site you agree to our Privacy Policy. We use cookies to keep you signed in and to measure site traffic. We do not sell your data.