A 41-year-old welder walks into a community emergency department at 2 a.m. with scald burns across his right forearm and the back of his hand after a radiator hose let go. The blisters are intact over most of it, but one patch on the dorsum of the hand looks paler and drier than the rest. The nearest burn center wants a size and a depth before it decides on transfer. Someone on the team photographs the arm and asks a general-purpose AI model for both numbers.
Bottom line: a general-purpose multimodal model sized burns about as well as emergency physicians in the first prospective ED study, but it missed most deep burns, and depth is what drives the transfer call. If you use one at all, use it as a second reader on burn size from standardized photos, and keep depth with the clinician.
The First Prospective ED Study
Aykut and colleagues ran a prospective, single-center diagnostic accuracy study in a tertiary emergency department in Türkiye from July 22 to September 8, 2025 [1]. Consecutive patients presenting within 24 hours of an acute burn were screened. The bedside clinician had to suspect partial-thickness or deeper injury; erythema-only burns were excluded. Of 413 screened presentations, 52 patients were enrolled, contributing 64 burn regions: 35 pediatric and 29 adult.
Each region was photographed in three standardized views on a smartphone: one straight-on and two oblique, at a long edge of at least 2,000 pixels, with a ruler or grid in frame when feasible [1]. The model, accessed as gpt-5-chat-latest through the OpenAI API with temperature set to 0, received the three photos plus age, sex, height, weight, and anatomical region. It returned each region's contribution to total body surface area (TBSA) and a depth class: superficial partial, deep partial, or full thickness.
Eighteen board-certified or board-eligible emergency physicians rated the same images and metadata, blinded to the model and to each other, after a brief calibration packet [1]. The reference standard was a three-member panel of one burn surgeon and two emergency physicians using age-appropriate Lund-Browder charts. The primary endpoint was noninferiority of the model's absolute TBSA error against the physician median, with a prespecified margin of 3 percentage points.
Size: Noninferior, With Caveats
The model met noninferiority. Its mean absolute TBSA error against the panel was 1.40 percentage points (median 1.00), versus 0.89 (median 0.75) for the physician median [1]. The paired median difference was 0.25 points, with a one-sided 95% upper bound of 0.50, well inside the 3-point margin. In 87.5% of regions the model landed within 3 points of the panel, compared with 96.9% for physicians.
Agreement told a less flattering story. Concordance with the panel was 0.642 for the model and 0.897 for physicians, and the model's 95% limits of agreement ran from -4.47 to +4.76 points against -1.20 to +2.76 for physicians [1]. Calibration showed a slope of 0.71 for the model, meaning it pulled large and small regions toward the middle, versus 1.01 for physicians. Error was similar in children (1.39 points) and adults (1.41 points). The study had too few large-TBSA regions to test the thresholds that matter for resuscitation.
Depth: Where the Model Failed
Depth agreement with the panel was slight for the model, with a quadratic-weighted kappa of 0.14 (95% CI -0.06 to 0.39), against 0.65 for physician consensus [1]. The panel rated 16 regions deep partial and 1 full thickness. The model called 13 of those 16 deep partial burns superficial partial, called the full-thickness burn superficial partial, and assigned full thickness to nothing. Raw exact agreement of 75% hid this, because most regions were superficial and the model labeled almost everything superficial.
The authors were direct. They concluded that the model's depth outputs should be treated as unreliable and nonactionable, and that depth-dependent decisions should remain clinician-led [1].
That failure sits directly on the referral criteria. The American Burn Association's 2022 referral guidelines call for immediate consultation with consideration of transfer for any full-thickness burn, partial-thickness burns of 10% TBSA or more, and any deep partial or full-thickness burn of the face, hands, feet, genitalia, perineum, or over a joint [2]. The welder's pale patch on the dorsum of the hand is exactly the finding the model was most likely to miss.
Other Models, Same Pattern
Two 2026 studies from a German group tested four commercial multimodal models on 50 clinical burn photographs, each image run five times per model. In the first, depth accuracy ranged from 34.0% to 76.4% across models and TBSA accuracy from 32.8% to 68.4%, and no model combined high accuracy with high run-to-run consistency [3]. Every model tended to overestimate depth, including assigning fourth-degree burns that were not in the dataset.
In the second, the same models detected burns versus unburned skin almost perfectly, 97.2% to 100%, with equivalent performance across Fitzpatrick skin tone strata [4]. When asked to choose debridement versus immediate grafting, accuracy fell to 24.8% to 72.8%, three models scored below the majority-class baseline, and agreement across repeated runs dropped to kappa 0.132 to 0.385 in three models.
Why Size Still Matters
Burn size estimation at the referring hospital is a known weak point. At a Swedish national burn center, referring physicians overestimated TBSA in 76% of 82 patients, with a median of 10% versus 6% by burn specialists, and discrepancies grew with burn size and with more than two separate burn areas [5]. In a Malaysian burn unit's review of 208 referrals, TBSA was overestimated in 60.6% and stated accurately in only 7.7% [6].
That is the gap a size-only second reader could address. The Turkish study does not prove it closes that gap, because its physicians were calibrated, its photos were protocolized, and its center had burn expertise on site [1]. The authors stated that performance in settings with less specialist expertise should not be assumed to improve. Downstream effects on transfer decisions or patient outcomes were not measured.
Key Takeaways
- In 64 burn regions, the model's mean TBSA error was 1.40 points versus 0.89 for emergency physicians, noninferior against a 3-point margin.
- The model called 13 of 16 deep partial burns superficial and missed the only full-thickness burn; depth kappa was 0.14 versus 0.65 for physicians.
- Use a general-purpose model only as a second reader on TBSA from three standardized views, and keep depth, and therefore the ABA transfer call, with the clinician.
- Referring clinicians overestimated burn size in 60.6% to 76% of referrals in two burn-center studies, so a size check is worth building and validating locally.
FAQ
Can ChatGPT estimate burn size from a photo?
In one prospective ED study, a general-purpose multimodal model estimated each burn region's share of TBSA with a mean error of 1.40 percentage points, noninferior to emergency physicians at 0.89 [1]. That held for three standardized, high-quality photos per region at a single tertiary center. It has not been validated for whole-patient TBSA, poor photos, or large burns.
Can AI tell how deep a burn is?
Not reliably yet. In the same study, the model classified 13 of 16 deep partial-thickness burns as superficial and missed the only full-thickness burn, with a depth kappa of 0.14 [1]. Separate testing of four commercial models found depth accuracy of 34.0% to 76.4% and inconsistent answers to the same image across runs [3].
When should a burn patient be transferred to a burn center?
The American Burn Association's 2022 guidelines recommend immediate consultation with consideration of transfer for full-thickness burns, partial-thickness burns of 10% TBSA or more, deep partial or full-thickness burns of the face, hands, feet, genitalia, perineum, or joints, suspected inhalation injury, chemical injuries, and high-voltage electrical injuries [2]. Burns in patients with comorbidities, concomitant trauma, or poorly controlled pain also qualify.
Dr. Chet's Take
I have been an emergency physician for more than 25 years, and as a TelEmergency medical director I support small rural emergency departments where the closest burn surgeon is a phone call and a helicopter away. That is exactly where a tool like this will show up first, and this article is right about the shape of it. The model can count. It cannot yet judge. Size is geometry, and geometry is what these systems are getting good at. Depth is a clinical read of color, moisture, blanching, and sensation, and a photograph strips out half of those cues before the model ever sees it. The core argument holds. Anyone who has watched a burn declare itself over 48 hours knows that even the bedside depth call is a first draft.
That being said, I think the article understates the real risk, which is the confident wrong answer on a hand. A superficial label on a deep dorsal hand burn does not just shrink a number. It changes the call from transfer to follow-up in clinic, and the error shows up weeks later as a contracture. The honest answer is that nobody knows how a tired clinician at three in the morning will weigh a clean machine answer against a pale, dry patch they are not sure about. My bet is the machine wins that argument more often than it should. That is an automation-bias problem, and the image model makes it worse because the photo looks like evidence. A number with a decimal point feels more objective than a nurse saying the skin looks waxy.
If you are the medical director of a small ED, decide now whether staff are allowed to paste patient burn photos into a consumer model at all, and write that down, because consent, privacy, and record-keeping questions arrive before the clinical ones. If you are the clinician on the call, give the burn center your own depth read first, and offer any size estimate from a tool as a cross-check, labeled as such. Then document the depth findings you actually saw at the bedside: color, blanching, moisture, and pinprick sensation, region by region. If your telemedicine or transfer platform already sends photos, ask the burn center what views they want so the images help a human reader first. The burn center can fix a size estimate on arrival. Nobody can fix a missed deep burn that never got transferred.
— Chester Shermer, MD, FACEP | Emergency Medicine, 25+ Years Clinical Experience | State Surgeon
Continue Your Training
If you're an emergency physician (or any clinician treating patients daily) trying to understand how AI will actually impact your clinical practice — not just the hype — I put together a free practical guide. You can download the AI in EM Survival Guide here.
Browse All Courses at Global MedOps Command
Relevant Reading on Global MedOps Command:
How to Avoid Becoming an AI Casualty — Dr. Shermer's guide to navigating AI tools in clinical and operational settings without compromising judgment or patient outcomes.
Emergency Department Efficiency Playbook — Practical systems for throughput, triage optimization, and operational efficiency.
Read more from Dr. Shermer on Medium
Connect with Dr. Shermer: LinkedIn — Chester "Chet" Shermer, MD, FACEP.
References
- Aykut A, Karayıl AR, Yıldırım C, et al. Multimodal large language model versus emergency physicians for burn assessment: a prospective non-inferiority study. Scand J Trauma Resusc Emerg Med. 2026;34(1):54. PubMed 41645231
- American Burn Association. Guidelines for Burn Patient Referral (Advice on Transfer and Consultation). 2022. ABA referral guidelines
- Güler I, Kraus A, Grieb G, et al. AI-based burn image assessment: reliability and clinical error patterns of multimodal large language models in a repeated-inference study. J Plast Reconstr Aesthet Surg. 2026;119:366-374. PubMed 42303556
- Güler I, Cambaz U, Kraus A, et al. Reliable detection, unreliable clinical decision-making: artificial intelligence models in burn assessment. Plast Reconstr Surg Glob Open. 2026;14(10):e8141. PubMed 42871867
- Kjölhede A, Dogan S, Karlsson M. Accuracy of burn size estimation in referred patients: a comparison between referring units and a Swedish National Burn Centre. Burns. 2026;52(9):108250. PubMed 42874527
- Ho HL, Halim AS, Sulaiman WAW, et al. Estimation of total body surface area burned: a comparison between burn unit and referring facilities. Ann Burns Fire Disasters. 2023;36(1):19-28. PubMed 38680901
Related simulation training: EM-Sim · Books by Dr. Shermer
Keep reading
Related reading and your next step.
Ready to go further? Move from this article into structured training, scenario-based rehearsal, and more physician-written guidance.
Course
Translate the article into a repeatable framework
Use the physician-led course when you want a structured framework for evaluating AI tools, protecting clinical judgment, and leading implementation decisions.
Simulation
Practice the decision path under pressure
Use EM-Sim when you want scenario-based repetition that turns article-level insight into physician-facing emergency-medicine reps.
Blog
Browse more articles
Explore the full blog for more on AI in emergency medicine, then head to the course and simulation pages when you want the structured next step.
Related Articles
AI in Emergency Medicine
AI Admission Scores in the ED: Where the 12 Minutes Came From
An AI admission score cut ED length of stay by 12 minutes at Mayo Clinic without more 72-hour returns. The gain came from earlier hospitalist conversations, and two other trials show why accuracy alone does not change care.
AI in Emergency Medicine
AI Pneumothorax Flags on Chest X-Ray: What a Clean Read Means
An AI overlay finds no pneumothorax on a supine trauma film. What the commercial tools detect on supine and upright films, why chest tubes fooled early algorithms, and when to look again with ultrasound or CT.
AI in Emergency Medicine
Smartwatch AF Alerts in the ED: What the Notification Proves
A patient arrives with a smartwatch atrial fibrillation alert and a sinus 12-lead. What the notification and the watch ECG can and cannot prove, what the ED studies show, and when anticoagulation evidence applies.